WESTERN MECHANICAL, INC. | Primary Dispatch: (661) 251-0111 | Toll-Free 24/7: (800) 585-5085 | CSLB #618138 (C-20 HVAC) | 100% UA Local 250 Union Trained

Industrial Cooling Tower Refurbishment & Basin Coating

Specification: BAC, Marley & Evapco Specialists • 10-Yr Basin Waterproofing

Baltimore Aircoil (BAC), Marley & Evapco cooling tower overhauls. Multi-layer epoxy basin relining, gear drive laser alignment, and fill pack replacement.

Direct Engineering Summary: Industrial Cooling Tower Refurbishment & Basin Coating

Replacing a corroded 500-to-2,000 ton rooftop cooling tower requires structural engineering, massive hydraulic crane mobilization, condenser piping modifications, and weeks of downtime—often exceeding $350,000+. Western Mechanical, Inc. (CSLB #618138, 100% UA Local 250) restores aging BAC, Marley, and Evapco cooling towers across Southern California for 40%–60% less via thick-film elastomeric urethane/epoxy cold-water basin coating, stainless panel rebuilds, and new PVC fill: (661) 251-0111.

Technical Specifications & Engineering Benchmarks

Benchmark Parameter Engineering Specification
Discipline ClassificationSPECIALTY • CSLB #618138 (C-20 HVAC)
Engineering SpecificationBAC, Marley & Evapco Specialists • 10-Yr Basin Waterproofing
Supported OEM PlatformsBaltimore Aircoil Company (BAC), Marley / SPX, Evapco, Reymsa, Delta Cooling Towers
Service Labor Standard100% UA Local 250 Union Trained • 0.78 EMR
Emergency Dispatch SLA< 2 Hours 24/7 Across Southern California • (661) 251-0111
Regulatory StandardsTitle 24 Part 6, SCAQMD Rule 1146, HCAI / OSHPD PIN 70
Industrial Cooling Tower Refurbishment & Basin Coating - Western Mechanical, Inc. CSLB #618138

Engineering Scope & Southern California Field Execution

Cooling towers are the thermal heat-rejection heart of every water-cooled central plant. Constant exposure to hard high-calcium water, atmospheric dirt, and chemical biocides causes severe galvanization corrosion, basin leaks, scale-fouled fill packs, and mechanical gearbox failures. Replacing a multi-cell cooling tower costs hundreds of thousands of dollars and weeks of crane downtime. Western Mechanical Inc. restores aging cooling towers to like-new thermal efficiency at a fraction of the replacement cost. We perform turnkey basin sandblasting and thick-film elastomeric epoxy recoating, crossflow and counterflow PVC fill pack replacement, high-efficiency drift eliminator upgrades, and precision drive shaft laser alignment.

Abrasive Prep, Seam Welding & High-Build Elastomeric Cold-Water Basin Waterproofing

Galvanized G-235 cooling tower cold-water basins pit along submerged bolted seams due to dissolved chlorides, dissimilar-metal galvanic cells, and aggressive oxidizing biocides—leaking treated condenser water onto structural roof decks below. Thin brush-on hardware-store paints peel off within months under continuous immersion and thermal expansion.

Western Mechanical drains, neutralizes, and mechanically power-abrade/media-preps corroded steel sumps to SSPC-SP2/SP3/SP11 bright metal, bolts or welds 304/316 stainless steel patch plates over perforated troughs, reinforces all seams with woven fiberglass tape, and applies multi-coat flexible polyurethane/polyurea immersion membranes rated for 10+ years of leak-free service.

Hot-Water Basin Re-Nozzling, Louver Reconstruction & ASHRAE 188 Biofilm Remediation

Porous rusted basin floors, UV-brittle sunlight-exposed louvers, and stagnant dead legs create ideal warm-water breeding grounds (77°F–108°F) for Legionella pneumophila amplification and algae slimes that foul chiller condenser bundles.

Alongside basin relining, our crews install cellular air-inlet sunlight-blocking louvers, replace rotted structural Eliminator supports with 316SS hardware, rebuild makeup float/electronic level assemblies, and perform hyper-halogenated pre-cleaning disinfection documented to ASHRAE Standard 188 and CTI Guideline WTB-148.

UA Local 250 Field Protocol & Certified Best Practices

Frequently Asked Questions: Industrial Cooling Tower Refurbishment & Basin Coating

Can a corroded, leaking cooling tower cold water basin be repaired without replacing the tower?

Yes. We drain, power-wash, abrasive blast to white metal, and apply an engineered multi-layer thick-film polyurethane or epoxy lining that seals all rusted seams and provides a durable 10-year waterproof seal.

How does replacing fouled tower fill improve chiller plant energy efficiency?

Fouled or scaled fill packs restrict air-to-water heat transfer, elevating condenser water return temperatures by 3°F to 8°F. For every 1°F drop in condenser water temperature, central chiller compressor energy drops by 1.5% to 2%.

What causes cooling tower fan vibration and how do you resolve it?

Vibration typically stems from failed bearing sleeves, misaligned drive shafts, or imbalanced composite fan blades. Our certified technicians perform dynamic in-place fan balancing and two-plane laser shaft alignment.

Acton Headquarters & 24/7 Industrial Cooling Tower Refurbishment & Basin Coating Dispatch

Western Mechanical, Inc. (Founded 1991) • 2210 Soledad Canyon Road, Suite O, Acton, CA 93510 • Primary Office: (661) 251-0111 • 24/7 Toll-Free Emergency Dispatch: (800) 585-5085 • CSLB #618138 (C-20 HVAC) | 100% UA Local 250 Union Trained.